Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
1.
Rev. bras. ter. intensiva ; 29(2): 180-187, abr.-jun. 2017. tab
Article in Portuguese | LILACS | ID: biblio-899503

ABSTRACT

RESUMO Objetivo: Analisar pacientes em pós-operatório de cirurgia cardíaca que necessitaram de reintubação endotraqueal, e identificar os fatores associados com óbito e seu relacionamento com escores de severidade. Métodos: Análise retrospectiva de informações referentes a 1.640 pacientes em pós-operatório de cirurgia cardíaca no período entre 2007 e 2015. Resultados: A taxa de reintubação foi de 7,26%. Dentre os pacientes reintubados, 36 (30,3%) foram submetidos à cirurgia de revascularização miocárdica, 27 (22,7%) à substituição valvar, 25 (21,0%) à correção de um aneurisma e oito (6,7%) a um transplante cardíaco. Dentre os pacientes com comorbidades, 54 (51,9%) eram hipertensos, 22 (21,2%) diabéticos e 10 (9,6%) tinham doença pulmonar. Dentre os pacientes que tiveram complicações, 61 (52,6%) tiveram pneumonia, 50 (42,4%) desenvolveram insuficiência renal e 49 (51,0%) tiveram uma forma moderada de distúrbio transitório da troca gasosa. Foi realizada ventilação não invasiva em 53 (44,5%) pacientes. A taxa de óbitos foi de 40,3%, e a mortalidade foi mais elevada no grupo que não recebeu ventilação não invasiva antes da reintubação (53,5%). Dentre os pacientes reintubados que morreram, os valores do SOFA e do APACHE II foram, respectivamente, de 7,9 ± 3,0 e 16,9 ± 4,5. A maior parte dos pacientes reintubados (47,5%) pertencia ao grupo de risco mais elevado (EuroSCORE > 6 pontos). Conclusão: A taxa de reintubação foi elevada e se relacionou com o SOFA e o APACHE II mais graves. A mortalidade foi mais elevada no grupo que não recebeu ventilação não invasiva antes da reintubação.


ABSTRACT Objectives: To analyze patients after cardiac surgery that needed endotracheal reintubation and identify factors associated with death and its relation with the severity scores. Methods: Retrospective analysis of information of 1,640 patients in the postoperative period of cardiac surgery between 2007 and 2015. Results: The reintubation rate was 7.26%. Of those who were reintubated, 36 (30.3%) underwent coronary artery bypass surgery, 27 (22.7%) underwent valve replacement, 25 (21.0%) underwent correction of an aneurysm, and 8 (6.7%) underwent a heart transplant. Among those with comorbidities, 54 (51.9%) were hypertensive, 22 (21.2%) were diabetic, and 10 (9.6%) had lung diseases. Among those who had complications, 61 (52.6%) had pneumonia, 50 (42.4%) developed renal failure, and 49 (51.0%) had a moderate form of the transient disturbance of gas exchange. Noninvasive ventilation was performed in 53 (44.5%) patients. The death rate was 40.3%, and mortality was higher in the group that did not receive noninvasive ventilation before reintubation (53.5%). Within the reintubated patients who died, the SOFA and APACHE II values were 7.9 ± 3.0 and 16.9 ± 4.5, respectively. Most of the reintubated patients (47.5%) belonged to the high-risk group, EuroSCORE (> 6 points). Conclusion: The reintubation rate was high, and it was related to worse SOFA, APACHE II and EuroSCORE scores. Mortality was higher in the group that did not receive noninvasive ventilation before reintubation.


Subject(s)
Humans , Male , Female , Aged , Postoperative Complications/epidemiology , Noninvasive Ventilation , Cardiac Surgical Procedures/methods , Intubation, Intratracheal/methods , Postoperative Complications/mortality , Postoperative Period , Severity of Illness Index , Retrospective Studies , Risk Factors , APACHE , Intubation, Intratracheal/statistics & numerical data , Middle Aged
2.
J. health sci. (Londrina) ; 18(3): 201-205, 31/07/2016.
Article in Portuguese | LILACS | ID: biblio-831807

ABSTRACT

A tomografia de impedância elétrica é um método não invasivo de visualização da mecânica respiratória beira-leito. Este exame permite observar, em tempo real, a ventilação regional pulmonar a cada ciclo respiratório com o objetivo de se otimizar e observar os efeitos imediatos dos ajustes de ventilação mecânica e\ou terapia respiratória. O objetivo é monitorar e avaliar a reexpansão pulmonar durante as manobras fisioterapêuticas de bloqueio torácico e hiperinsuflação pulmonar com AMBU® por meio do tomógrafo de impedância elétrica. Apresentação dos resultados e a interpretação da monitorização pela tomografia por impedância elétrica torácica em paciente vítima de trauma cranioencefálico, com diagnóstico de pneumonia em hemitórax esquerdo, internado na Unidade de Terapia Intensiva submetido à manobra de bloqueio torácico e a manobra de hiperinsuflação pulmonar. Previamente à manobra de bloqueio torácico, as porcentagens de áreas ventiladas foram: quadrante 1 50%, quadrante 3 34%, quadrante 2 3% e quadrante 4 11%. Após a manobra os resultados obtidos foram: quadrante 1 50%, quadrante 3 22%, quadrante 2 14% e quadrante 4 13%. Na hiperinsuflação pulmonar, previamente as porcentagens de áreas ventiladas foram: quadrante 1 33%, quadrante 3 25%, quadrante 2 22% e quadrante 4 19%. Após a hiperinsuflação pulmonar os resultados obtidos foram: quadrante 1 39%, quadrante 3 22%, quadrante 2 23% e quadrante 4 15%. Após as manobra de bloqueio torácico há redistribuição da ventilação pulmonar no pulmão contralateral e na hiperinsuflação pulmonar houve redistribuição da ventilação pulmonar em ápices pulmonares e redução em bases. A monitorização também mostra que essas manobras são eficazes para reexpansão pulmonar.


Electrical impedance tomography is a noninvasive method of visualizationof bedside respiratory mechanics. This exam allows to observe, in real-time regional lung ventilation to each] respiratory cycle with the aim of improving and observing the immediate effects of mechanical ventilation settings and or chest therapy.The goal is to monitor and evaluate the pulmonary re-expansion during chest therapy maneuvers of thoracic blockade and lung hyperinflation with Ambu® by electrical impedance tomography. Presentation of the results and interpretation of monitoring was carried out by thoracic electrical impedance in a patient victim of head trauma, diagnosed with pneumonia in the left hemithorax, admitted to the Intensive Care Unit and submitted to thoracic blocking maneuver and lung hyperinflation maneuver. Before thoracic blocking maneuver, the percentages of ventilated area were: quadrant 1 50% 3 34% quadrant, quadrant 2 and quadrant 3% 4 11%. After the maneuver the results obtained were: Quadrant 1 50% 3 22% quadrant, quadrant 2 and quadrant 4 14% 13%. In lung hyperinflation, previously the percentage of ventilated area were quadrant 1 33% 3 25% quadrant, quadrant 2 and quadrant 22% 4 19%. After lung hyperinflation the results obtained were: Quadrant 1 39% 3 22% quadrant, quadrant 2 and quadrant 4 23% 15%. After the thoracic blocking maneuver there is redistribution of pulmonary ventilation in the contralateral lung and lung hyperinflation there was redistribution of ventilation pulmonary apices and reduction in basis. Monitoring also shows that these maneuvers are effective for pulmonary re-expansion.

3.
Sci. med. (Porto Alegre, Online) ; 26(1): 22678, jan-mar 2016. graf.
Article in Portuguese | LILACS | ID: biblio-836864

ABSTRACT

OBJETIVOS: Comparar valores de pressão inspiratória máxima (PImáx) aferidos por um manovacuômetro digital e por um dispositivo eletrônico de treinamento muscular inspiratório e avaliar as repercussões hemodinâmicas após as medidas. MÉTODOS: A amostra foi composta por indivíduos acima de 18 anos, de ambos os sexos, internados na unidade de terapia intensiva, hemodinamicamente estáveis, sem uso de drogas vasoativas ou de sedação, intubados ou traqueostomizados, em processo de desmame da ventilação mecânica. Foram feitas três medidas de PImáx pelos dois equipamentos, com tempo de oclusão de 20 segundos e tempo entre as medidas de cinco minutos. Foram analisados frequência respiratória, pressão arterial média e frequência respiratória antes e após cada medida para cada equipamento utilizado. A análise estatística usou os programas Statistical Analysis System e R Project for Statistical Computing V. 3.1.2, aplicando os testes ANOVA e Wilcoxon. RESULTADOS: Foram incluídos no estudo 58 pacientes. A média das PImáx obtidas com o manovacuômetro digital foi -46,22 centímetros de água (cmH2O), enquanto a média obtida com o dispositivo de TMI foi -13,15 cmH2O (p<0,001). A frequência cardíaca apresentou aumento na comparação antes e após todas as medidas em ambos os dispositivos (p<0,0001). A pressão arterial média apresentou diferença estatisticamente significativa somente entre antes e após a primeira medida obtida pelo manovacuômetro digital, e entre antes e após a segunda medida obtida com o dispositivo de treinamento muscular inspiratório (p<0,001). A frequência respiratória apresentou variação significativa entre antes e após as três medidas em ambos dispositivos (p<0,0001). Os valores das variáveis hemodinâmicas após as medidas de PImáx permaneceram dentro dos limites da normalidade. CONCLUSÕES: O manovacuômetro digital registrou uma PImáx superior à registrada pelo dispositivo eletrônico de treinamento muscular inspiratório. Ambos os dispositivos alteraram os valores das variáveis hemodinâmicas, que entretanto permaneceram dentro da normalidade e sem repercussão clínica.


AIMS: To compare maximum inspiratory pressure (MIP) measured by a digital manometer and by an inspiratory muscle training (IMT) device and to evaluate hemodynamic changes after measurements. METHODS: The sample included male and female individuals older than 18 years admitted to an intensive care unit who were hemodynamically stable, not being treated with vasoactive drugs or sedated, intubated or tracheostomized, and who were in the process of being weaned from mechanical ventilation. MIP was measured by both devices on three different occasions, with an occlusion time of 20 seconds and a 5-minute interval between measurements. The following parameters were assessed: respiratory rate, mean arterial pressure, and respiratory rate before and after each measurement by each device. The statistical analysis was made in the Statistical Analysis System and the R Project for Statistical Computing V. 3.1.2 softwares, using the ANOVA and the Wilcoxon tests. RESULTS: Fifty-eight patients were included in the study. The mean value obtained for MIP was -46.22 centimeters of water (cmH2O) in the digital manometer and -13.15 cmH2O (p<0.001) in the IMT device. Heart rate showed a significant increase (p<0.0001) both before and after all measurements in both devices. Mean arterial pressure showed a statistically significant difference only before and after the first measurement by the digital manometer and before and after the second measurement by the IMT device (p<0.001). The respiratory rate oscillated significantly before and after the three measurements by both devices (p<0.0001). The hemodynamic parameters remained within reference values after MIP measurements. CONCLUSIONS: The digital manometer recorded a higher MIP than that measured by the IMT device. The hemodynamic parameter values oscillated in both devices, but they remained within the normal range and were not clinically significant.


Subject(s)
Humans , Male , Female , Respiration, Artificial , Respiratory Insufficiency , Respiratory Tract Diseases , Ventilator Weaning , Maximal Respiratory Pressures , Intensive Care Units
SELECTION OF CITATIONS
SEARCH DETAIL